Forum Post: RE: Stress range

$
0
0
Hello Chesta, AutoPIPE is able to set only one ambient temperature. You have the following options: 1. Create multiple models of the same configuration, each with a different ambient temperature as needed 2. Create a single model with multiple Thermal / Pressure cases, assigning the correct temperature for T1 along the pipe. Under Tool Model options Results No. of thermal ranges, enter the number of press/temp cases in the model. see online help for details on this option. This will add a number of thermal cases T1-T2, T1-T3, etc.. Regards, Mike Dattilio Bentley TSG Support Analyst ===================================================