Forum Post: RE: Advance Modeling of Single Tied Expansion Joint

$
0
0
Hello Jaroslaw.K, Are you talking about the following displayed in the Tools Model consistency check report:       * * * W A R N I N G - MODEL * * *          W726-12: Following Segment(s) not connected to other segments and has no anchors   This is not an error but a warning for the user to know that the following has occurred. Regardless try and run the analysis. If the analysis runs without a displayed error, then the tie-rods were correctly connected and supported from the beams.   If you see the following displayed,     E801-1:   FATAL ERROR : Unstable system. Need support at node xxx    Dir xx Then yes, there is a problem that needs to be addressed. Otherwise,  you are fine. On a different subject, you should have noticed from the webinar that the tie-rods have assigned rigid properties to include both weight and thermal movement. Regards, Mike Dattilio Bentley Technical Support Analyst Web: selectservices.bentley.com Create your Service Request online!  Log in to SELECTservices Online via selectservices.bentley.com and then go to My Support Account Service Request Manager.  You'll have the ability to create a new Service request, view all Service Requests created by you or anyone else in your company, and view statistics on previous requests.