I must check loads on pump's nozzles according to API610. My nozzle's diameters are greater then DN400 (in SI units) and allowable loads (forces and moments) are described by pump vendor. Is it possible in such case to use build in AutoPIPE tool (Rotating Equipment check) to compare my calculated loads with allowables? How can I input allowable loads for my nozzles to AutoPIPE and get a report about pump check results? Regards
↧
Forum Post: Analysis of pump nozzle's loads according to API610 for nozzles dia greater than DN400
↧