Wiki Page: Import and Export issues in PULS

$
0
0
Applies To Product(s): PULS Version(s): XM Environment: N/A Area: Import and Export Subarea: Original Author: Bentley Technical Support Group Item #1: Could you please explain us how the number of nodes is counted in the program?!  Answer: Please see the following conversion from AutoPIPE to PULS. Valve: AutoPIPE = 3, Puls =2   Bend: AutoPIPE = 3, Puls =1 Tee: AutoPIPE = 2, Puls =3 When importing AutoPIPE models into PULS, support nodes are removed to allow import of larger models. Maximum number of nodes supported in PULS is limited to 1000 for PULS Option 3 and 400 for other versions.   See Also Bentley AutoPIPE External Links Bentley Technical Support KnowledgeBase Bentley LEARN Server Comments or Corrections? Bentley's Technical Support Group requests that you please submit any comments you have on this Wiki article to the "Comments" area below. THANK YOU!