Use the following procedure to help fix files that cause AutoPIPE to display the following when importing an NTL file created from a translated PCF file:
---------------------------
Confirm
---------------------------
Import process aborted. Review error messages :
---------------------------
Yes No Cancel
---------------------------
- When the following appears; select the "Yes" button.
AutoPIPE report viewer should have automatically opened the SYSTEMNAME.msg file from the same folder location where the PCF file was stored.
Scroll down to the bottom of the listing to see the number of errors:
Search the entire file for these three Error locations:
Navigate to the folder where the PCF file is located, searching for the PCF translated NTL file. Open the SYSTEMNAME.NTL file in any word processor (NotePad, WordPAD, MS Word, etc..).
Note: best to have an word processing applcaition (i.e. NotePAD++, UltraEDIT, etc..) that displayes the current cursor location with both column and row indicators..Start AutoPIPE, please see the following AutoPIPE help section:
Help > Contents> Search Tab> enter "Command Card Reference" (include the quotes), press List Topics button, double click on the selected topic from the list provided to see more information.
Using the command card reference in conjuction with the error message, investigate the NTL file to locate and fix the issue. When you have corrected the problem, save the NTL file to a different name (example: test1.NTL), and back inside AutoPIPE select File> Open> AutoPIPE Batch (*.NTL) to open the file again.
If everthing was corrected, the model should be displayed.
If the file caused the application to abort again, start the same process over from the top using the new file.