Wiki Page: AutoPIPE Stress Iso - Errors / Warnings Detected

$
0
0
Applies To Product(s): AutoPIPE, Version(s): 2004, XM, & V8i Environment: N/A Area: Stress Iso Subarea: Original Author: Bentley Technical Support Group Problem: What are some general Stress Iso warnings and how to resolve them?   Answer: UNABLE TO POSITION: 'REFERENCE DIMENSION' UNABLE TO POSITION: 'Support' UNABLE TO POSITION: 'MESSAGE-ROUND' Troubleshooting: 1.  See the following file to be sure that no known issues are present in the current model; especially A1.Disconnected Pipeline: C:\ Bentley\ AutoPIPE V8i SELECTseries\ StressISO_Troubleshooting.pdf    2. Known issue, changing segment at a reducer start point or end point. The following has been logged:  TFS-D123552: Stress ISO Export failed if near/far end of REDUCER were on segment continuation point Fix, select node point shared by both egments, (ex. W15) and then join segment by going menu Edit Segment Join.  See Also Bentley AutoPIPE External Links Bentley Technical Support KnowledgeBase Bentley LEARN Server Comments or Corrections? Bentley's Technical Support Group requests that you please submit any comments you have on this Wiki article to the "Comments" area below. THANK YOU!