Wiki Page: Q. How to resolve issue with bracket type selection when using AutoPIPE Vessel?

$
0
0
Applies To Product(s): AutoPIPE Vessel Version(s): ALL Area: Modeling Date Logged & Current Version March 2018 40.06.00.07 Problem: Text Solution: AutoPIPE Vessel offers various design standards for bracket design viz. APVessel, Technip, Foster etc. There may be certain instances when the program may not execute with selection of the above standards, however there is a workaround for this at the moment. Workaround From the drop down menu select the desired standard eg. APVessel. Then click on the drop down menu once again and change the selection to “User Defined” as shown below. Observe that all the fields still have the same value and nothing has changed from the previous selection (APVessel in this case) except that the fields which were earlier disabled or greyed out have become active now. Click “OK” and proceed with the strength calculations. The program should be able to execute this time without any issue. See Also Crashed issues AutoPIPE Vessel Bentley LEARN Server

Viewing all articles