Applies To Product(s): AutoPIPE Vessel Version(s): All Environment: N/A Original Author: Bentley Technical Support Group Date Logged & Current Version July 2023 43.01.01.011 Problem: When user try to run a model with a half pipe coil on the cylindrical shell in ASME VIII Div.1, the calculation is interrupted by an error. forrtl: severe (408): fort: (11): Subscript #1 of the array DN80 has value 0 which is less than the lower bound of 1. Why does this happen and how to avoid? Solution: When we design half pipe coil on the cylindrical shell as per ASME VIII Div.1, Non Mandatory Appendix EE, Figure EE-2 gives curves only for shell thicknesses above 5mm. Refer below image. If user enters shell thickness below 5mm, software gives an error. This is a bug and we are working on this issue. As a workaround use shell thickness 5mm or above to avoid the error. See Also Error Message Bentley AutoPIPE Bentley LEARN Server
↧