Notes: if an enhancement or defect has not been added to the program, log an Service request for that enhancement. The more requests logged per an enhancement, the quicker the CAE development team will add that feature to the program. The following enhancements and defects have already been requested: Bug 1346363 Flange Bolt library: correct course thread library values from standard B1.1 2003 Tables 6, 7, and 11 ADO ===================================================================================== TFS Defect 854258 HDPE Pipes are not accepting nominal size 1.5 inch in pipe properties Enhancement 709088 Add new valve catalog / library for Velan Enhancement 696066 Add table to Beam Section Profile Database dialog to display a fraction of beam properties before selecting Enhancement 696051 Add solid square shaped to beam library Enhancement 672545 Add GOST 32388 code approved materials to B31.3 material library Enhancement 346476 No warning provided by the program when the thickness selected for a specification exceeds allowable thickness range and fall below the allowable thickness range Description: No warning is provided by the program when the thickness selected for a material specification exceeds maximum or minimum thickness range. Steps to repeat: First scenario: 1. Create a new SPC-2 model setting the Input and Output units to SI 2. Create a new pipe ID, setting the schedule to NS and setting the wall thickness as 70 mm 3. On the Pipe Properties dialog, select Pipe Material as SS1330-08 Note that no warning or error message is displayed by the program. 4. Press OK on the Pipe properties dialog and and invoke Tools > Library 5. Select "Table type" as Specs, "Library name" as AUTONGSS, and action as scan and press OK on the Library dialog 6. Search for SS1330-08 on the AutoPIPE Report Viewer Notice that the maximum thickness set for SS1330-08 is 60 mm. Second scenario: For code SNIP-97, some materials do not have any value for Minimum yield and Ultimate Strength for thickness range <=6 in code. So when thickness is selected for this range in Pipe Properties dialog, no warning is given by the program. Following are the materials affected. 10_D153 10ps_D153 10kp_D153 St2kp_D153 St2sp_D153 St2ps_D153 Avoidance: None Enhancement 368968 Add EN 1092-1 flange library Description: Add En1092-1 to the General Model options Libraries - Component drop down listing Enhancement 208153 Add New 1.0565 Material to EURO2002, EURO2009 and EURO2012 Description: For the material libraries EURO2002, EURO2009 and EURO2012, add the following material: 1.0565. Online help shall also be updated to include this reference. Enhancement 205025 Updated outdated AUTOFRP library Description: Update the AutoFRP library with updated information. Enhancement 110638: Tracker#: 3310 Add solid pipes to beam library See Also Enhancements Requests and Logged Defects Bentley AutoPIPE
↧