Quantcast
Channel: AutoPIPE
Viewing all articles
Browse latest Browse all 16073

Wiki Page: 15. "Edit" Commands Enhancements & Defects for AutoPIPE

$
0
0
Enhancements and defects for Edit commands: Selecting Undo Redo Cut Copy Paste Delete Move/Stretch Rotate Scale Segment Renumber Goto Point Beam.. Goto Beam Next Beam Prev Beam Note: if an enhancement or defect has not been added to the program, log an Service request for that enhancement. The more requests logged per an enhancement, the quicker the CAE development team will add that feature to the program. The following enhancements and defects have already been requested: Defect 889911: Program crash on copy if model has a segment that starts at valve end Updated Version: TBD Work Around: For new models: Don't start new segment at end of valve. For existing models: Join the two segments (Home > Segment > Join) OR Insert a piping point after valve, which is in same segment as of the valve Defect 782853: Copy/Paste: new pipe id is created on paste even same pipe id exist in model Updated Version: TBD (No number) AutoPIPE v 12.04 reported issue: Node point selection jump to random location Work Around: - Download and install AutoPIPE 23.00.01.367 or higher. - If unable to upgrade, accept the issue and continue to try and select the correct node point using: a. Mouse and Left mouse button to select node point. b. Goto point command c. Make modifications directly in the input grids as needed. ================================================================ Defect 759465: Rotate dialog limits the angle to be 5 characters only Updated Version: 12.07 Enhancement 723766: Dynamic analysis dialog: Pressing OK shall remove the unavailable support groups from response spectrum load sets Steps to Repeat: 1.Open MSRS_Example model 2.Delete imposed displacement at point 17 3.Running "Consistency Check" reports "W2143-29:Response spectrum case R1 has support group 3 that is no longer defined in model." 4.Running "Analyze All" command gives message "E801-24: Number of MSRS groups is inconsistent with SAM case" 5.Open dynamic analysis dialog and go to Response Spectrum tab 6.Click on define button in Spectra column 7.Notice that the support group 3 is not available. 8.Press OK, and again press OK to close dynamic analysis dialog. 9.Run consistency check and analyze all commands and notice that the message is still given. Workaround: - Open dynamic analysis dialog - Go to Response Spectrum tab. - Click on define for load sets reported in consistency check - Change a single scale factor or just write same value again. - Click apply button & then click OK. - Click OK to close dynamic analysis dialog. - Run Consistency check and Analyze All commands and notice that no message is given this time. Enhancement 197854: Copy / Paste piping with buoyancy loads Enhancement 121179: Add feature to use mouse in specifying rotate point. Enhancement 101317: Tracker#: 1231 Rotate geometry, supports, local and global static loads See Also Enhancements Requests and Logged Defects Bentley AutoPIPE

Viewing all articles
Browse latest Browse all 16073

Trending Articles



<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>