Applies To Product(s): AutoPIPE, Version(s): 2004, XM, & V8i Environment: Enhancements Area: Subarea: Original Author: Bentley Technical Support Group The following Dynamic Analysis enhancements have been logged for inclusion into a future version of AutoPIPE: Note: if an enhancement has not been added to the program, log an Service request for that enhancement. The more requests logged per an enhancement, the quicker the CAE development team will add that feature to the program. 1. CAE-CR-10998 Program should block dynamic analysis if static analysis set #1 not analyzed Program should block dynamic analysis if first analysis set not analyzed. There is an internal limitation of the program that the first static analysis set should always be selected for analysis if there is any dynamic analysis to be performed for the model. AutoPIPE historically had only 1 load set prior to 9.1.0, all of the definitions related to dynamic load cases etc used to be associated with this single load set. In the new system – this older load set is mapped to the first static analysis set. Corrected Version: 9.6.0.10 2. CAE-CR-4560: Add the ability to import time history load file from Bentley HAMMER. Corrected Version: TBD 3. TFS-E139516: Add feature to apply 15% Peak Spectrum Broadening for dynamic analysis per NRC Guide 1.122. Corrected Version : TBD See Also Bentley AutoPIPE External Links Bentley Technical Support KnowledgeBase Bentley LEARN Server Comments or Corrections? Bentley's Technical Support Group requests that you please submit any comments you have on this Wiki article to the "Comments" area below. THANK YOU!
↧