Applies To Product(s): AutoPIPE, Version(s): 2004, XM, & V8i Environment: N/A Area: Error Subarea: Original Author: Bentley Technical Support Group Problem: After conducting analysis I got error: --------------------------- Error --------------------------- E90-21: Analysis results do not exist --------------------------- OK --------------------------- What can be the reason? Answer: Could this be a case that your model was created/analyzed in older version of AutoPIPE and you are now reviewing it in later version? There was a known issue – if model is analyzed in a previous version and results exist for it then if you open same model in a newer AutoPIPE version and try to access results without analyzing it you will receive such error. This locks some of the result file(s). After this even if you select delete results and analyze again you will still see the same error on all result options (ex. Results Grids, Results displacement, ec..) except the Results Output report. Avoidance: There are 4 different avoidance that have all worked for various models. You may need to try more than 1 solution below for your model to be fixed, save the original model in a safe location and perform each of the following avoidance on a folder containing a copy of the original model files: Avoidance #1: 1. With your model opened in AutoPIPE, select Analyze All, the program runs the analysis in the background. 2. Open the Combinations dialog screen and select the Load Cases tab: 3. Confirm that "Ignore for Def. Code comb" check-boxes are all checked for all load-cases. Avoidance #2: 1. Select Analyze Delete Analysis Results choose all available analysis sections, and press OK button. 2. Select Analyze All, the program runs the analysis in the background 3. Select Results Grids and / or Output Report to confirm results have been created. Avoidance #3: 1. Close the model 2. Close the instance of AutoPIPE 3. Manually delete all files including combination files from the model directory and only retain the .dat model file 4. Restart AutoPIPE and re-open your model. 5. Select Analyze All, the program runs the analysis in the background 6. Select Results Grids and / or Output Report to confirm results have been created. Avoidance #4: Note: this solution worked best if error was displayed while trying to view the Stress Summary dialog 1. Open your model 2. Select Load Static analysis 3. Select Delete All button, and press Yes. 4. Recreate all Load Set as required. 5. When completed, press OK button, and run Analyze All 6.Review, Tool Combinations all tabs to be sure combinations are created and are correct per your analysis requirements. If the above does not work, complete the following: If the above does not work, follow procedures to file a service request and send us your model for review. See Also Bentley AutoPIPE External Links Bentley Technical Support KnowledgeBase Bentley LEARN Server Comments or Corrections? Bentley's Technical Support Group requests that you please submit any comments you have on this Wiki article to the "Comments" area below. THANK YOU!
↧