Applies To Product(s): AutoPIPE Version(s): 2004, XM, & V8i Environment: N/A Area: FAQ Subarea: Original Author: Bentley Technical Support Group First review AutoPIPE limitation in the online help: Please see the following AutoPIPE help section: Help > Contents> Search Tab> enter "Save Defaults" (include the quotes), press List Topics button, double click on the selected topic from the list provided to see more information. Item #1, Question: What is the maximum pipeline length we can model in AutoPipe? Answer: You can model any length of pipe line as long as the model database does not exceed the 10,000 node point limitation and the coordinate location values. Item #2, Question: Is there a limit on the number of digits for the coordinates in Autopipe? We have a project that has the following plant coordinates, 202094'4.875", that we want to use in Autopipe. Answer: Yes there is a limit. On the Input grid's, point tab, Global X, Y, & Z values are limited to input 8-9 place values regardless of the value that can actually be entered (max =15 place value). As a general rule of thumb, suggest trying to restrict this field to about 8-9 values (example 1234.6789, or 123456.89). Another option, change the unit of measurement used for coordinate in the respective Unit input file (*.UNT) specified on Tools> Model Options> General> Unit Input. Instead of using Feet use yards, mile, furlong, etc..
↧