Hello Hugo, By default AutoPIPE does not create code combinations for just Tresca stress or Maximum Octahedral shear (Von Mises) stress. However, if you wish to please create new code combinations as needed. Example, using AutoPIPE V8i 09.06.01.10 1. Tools> Combinations 2. Select New button 3. Enter a name and description (optional). 4. Select a Combination method. 5. Select a Category (Von mises or Tresca) 6. Add load case to be combined for code equation. 7. Press OK to close combination dialog. Regards, Mike Dattilio Bentley TSG Support Analyst ===================================================
↧