Wiki Page: 07. Why is that there is a big discrepancy between the AutoPIPE Hanger Analysis reported values and the Static Analysis results ?

$
0
0
Applies To Product(s): AutoPIPE, Version(s): 2004, XM, & V8i Environment: N/A Area: Subarea: Original Author: Bentley Technical Support Group Problem: Why is that there is a big discrepancy between the AutoPIPE Hanger Analysis reported (5.652 mm) value and the Static Analysis results (5.97mm) ? Answer: Suggest reviewing how spring hangers are selected from AutoPIPE's online help shown at the top of the previous WIKI page . Note that the Spring Hanger Analysis module selected the first spring with the longest range and highest spring that satisfies the conditions of the analysis for thermal movement only. After running a hanger selection, AutoPIPE automatically updates the supports with the hanger selection information to be used in the actual Static / Dynamic analysis for operating conditions. Therefore, YES the thermal movement for the Spring Hanger report (i.e. 5.62 mm) may differ from that of the Static / Dynamic Analysis results (i.e. GT3P3E1(4)). This is expected behavior. See Also Bentley AutoPIPE External Links Bentley Technical Support KnowledgeBase Bentley LEARN Server Comments or Corrections? Bentley's Technical Support Group requests that you please submit any comments you have on this Wiki article to the "Comments" area below. THANK YOU!