Problem:
The following is displayed in model consistency check report:
W726-7: Pipe diameter change without a reducer at point XXX
Solution:
This warning message is displayed whenever there is a difference in pipe properties OD or wall thickness between two sucessive points in a model without a reducer.
Avoidance:
Option #1:
Insert a reducer between the 2 different pipe properties.
Option #2:
Accept the warning as OK, and ignore the warning as the joint is correctly modeled. Insert a user Joint type / SIF added as needed.