Wiki Page: W726-7: Pipe diameter change without a reducer at point XXX

Image may be NSFW.
Clik here to view.

Problem:

The following is displayed in model consistency check report:

W726-7:  Pipe diameter change without a reducer at point XXX

Solution:

This warning message is displayed whenever there is a difference in pipe properties OD or wall thickness between two sucessive points in a model without a reducer.

Avoidance:

Option #1:


Insert a reducer between the 2 different pipe properties.

Option #2:


Accept the warning as OK, and ignore the warning as the joint is correctly modeled. Insert a user Joint type / SIF added as needed. 