Applies To Product(s): AutoPIPE, Version(s): 2004, XM, & V8i Environment: N/A Area: Subarea: Original Author: Bentley Technical Support Group Problem: I'm in the process of getting AutoPipe 09.05.00.21 packaged and noticed it's using an MSI now, good thing. My question, is there a command line switch I can use the change the installation folder? We don't install to the C:\ root unless absolutely necessary. I would like to place AutoPipe under C:\Program Files as I would with most other Bentley applications. Answer: Yes, if Setup.exe is run with INSTALLLOCATION defined, AutoPIPE will be installed in the defined location. For example: Setup.exe INSTALLLOCATION="C:\Program Files (x86)\Bentley\Engineering\AutoPIPE V8i SELECTseries 4" To automate the installation, please refer to the WiX installer section above for more details The translator installers are hardcoded with the installation location, unfortunately. However, they can be repackaged for you with the desired installation location. Please log a service ticket referencing this WIKI page and specify the path where you want the translators to be installed. See Also Bentley AutoPIPE External Links Bentley Technical Support KnowledgeBase Bentley LEARN Server Comments or Corrections? Bentley's Technical Support Group requests that you please submit any comments you have on this Wiki article to the "Comments" area below. THANK YOU!