Applies To Product(s): AutoPIPE, Version(s): V8i Environment: N/A Area: Warning, Library Subarea: Original Author: Bentley Technical Support Group Problem: While using AutoPIPE, the following warning appears, W726-39: Allowable at XX is outside of temperature range at point XXX for material XXXX Why? how to resolve? Answer: There are 2 reasons why this warning would appear: Reason #1: According to the Library data and material properties specified, temperature load case(s) may be requesting a library value that is outside of the range of data in the library. Review the material library to confirm data temperature is within the data range specified in the library. A. Start AutoPIPE, and select Tool> Library> Table type = Spec, Library name = B313-10, Action = Scan: Press OK button B. AutoPIPE Viewer appears with the B313-10.lib Material section. C. Find the SPECIFICATION material in the document using the search tool (example: A53-A). D. Noticed the temperature range for the material (example: A53-A = -20 deg F to 1100 deg F) . If the temperature load case (ex. T1) for the specified node point is outside of this range the warning will be displayed. Reason #2: If a new customized material library has been created and used, the warning above may appear if there are problems with the material file. Review the SRC file and compiled errors to determine any potential problems. See Also Bentley AutoPIPE External Links Bentley Technical Support KnowledgeBase Bentley LEARN Server Comments or Corrections? Bentley's Technical Support Group requests that you please submit any comments you have on this Wiki article to the "Comments" area below. THANK YOU!
↧