Quantcast
Channel: AutoPIPE
Viewing all articles
Browse latest Browse all 16073

Wiki Page: 05. PXF Importing Duct work AutoPlant components crashes AutoPIPE, why?

$
0
0
Applies To Product(s): AutoPIPE, Version(s): 2004, XM, & V8i Environment: N/A Area: Import Subarea: Original Author: Bentley Technical Support Group Dec 2014, AutoPIPE V8i 09.06.01.10 Problem: Importing Duct work AutoPlant components crashes AutoPIPE, why? Answer: From the online help: AutoPIPE recognizes the following components: PIPE pipe component VALV valve FLAN flange ELBO elbow REDU reducer RIGD rigid pipe with specified diameter DEL ignore nodes associated with this component AutoPLANT has more component names in the connectivity file than those listed above, so it becomes important to map any item type used in PXF file into one of the above listed components. In addition, PXF Item Type Numbers: AutoPLANT PXF file has currently 20 different item types. The item type number is given under the field 2000 / 2100 in the PXF file. These types are listed below: 0 PIPE COMPONENT 1 ELBOW 2 180 DEGREE BEND 3 TEE , Y or Y STRAINER 4 CROSS 5 CONCENTRIC REDUCER 6 ECCENTRIC REDUCER 7 IN-LINE FITTING: COUPLING, UNION, ETC. 8 END OF LINE FITTINGS: CAPS, PLUGS, ETC. 9 OLET, STUB IN 10 SINGLE VALVE 11 ANGLE VALVE 12 3WAY VALVE 13 4WAY VALVE 14 FLANGE 15 GASKET 16 BOLT 17 TRUNNION, BASE ELL/LINE SUPPORT, SPRING, HANGER 18 SHOE, GUIDE 19 WELD GAP 51 EXPANSION JOINT 99 END CONNECTION TYPE Therefore if your exported PXF file does not contain component item numbers supported by AutoPIPE, the component can not be imported. Thus, crashing the program. Fix: Confirm exported components from AutoPLANT are converted to AutoPIPE components that can be imported into the program. Note: According to the CADAP.MAP file, all AT_HVAC_xxxxxx components are mapped to (16) BOLT, which are ignored (i.e. not mapped to an actual AutoPIPE component like Pipe, Elbow, etc..). As already known, ducts are used in heating, ventilation, and air conditioning (HVAC) to deliver and remove air. The mapping in CADAP.map of all HVAC -> BOLT is done intentionally to skip any HVAC components during PXF import. AutoPIPE does not have square pipe data in it's libraries. There is one enhancement that has not been added to the program related to this issue ( CAE-CR- 3338 ). Only workaround is to import HVAC into AutoPIPE and map it to circular pipe run and other components. This can be done by removing the mapping of HVAC_ components from the CADAP.map file (delete all occurrence of "AT_DUCT_xxxx" from the CLASS MAPPING TABLE). By doing so the application will display prompts for the user to map components to existing supported components during import. See Also Bentley AutoPIPE External Links Bentley Technical Support KnowledgeBase Bentley LEARN Server Comments or Corrections? Bentley's Technical Support Group requests that you please submit any comments you have on this Wiki article to the "Comments" area below. THANK YOU!

Viewing all articles
Browse latest Browse all 16073

Trending Articles



<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>