Wiki Page: 05. ASME B31.3-2010 Occ Allowable is incorrect in AutoPIPE V8i 09.04.xx.xx, why?

$
0
0
Applies To Product(s): AutoPIPE, Version(s): 2004, XM, & V8i Environment: N/A Area: Subarea: Original Author: Bentley Technical Support Group Dec 2014, AutoPIPE V8i 09.06.01.10 Problem: ASME B31.3-2010 Occ Allowable is incorrect in AutoPIPE V8i 09.04.xx.xx, why? Answer: There is a known issue that was logged against that version of the program: TFS-D138808 (CAE-TR-10782) - B31.3-2010 Occasional allowable may be unconservative for T Model options> Results> Use Alt. Occ. Allow, check OFF. 4. Upgrade to a newer version (AutoPIPE V8i 09.05.01.xx and Higher). See Also Bentley AutoPIPE External Links Bentley Technical Support KnowledgeBase Bentley LEARN Server Comments or Corrections? Bentley's Technical Support Group requests that you please submit any comments you have on this Wiki article to the "Comments" area below. THANK YOU! ASME B31.3-2010 Occ Allowable is incorrect in AutoPIPE V8i 09.04.xx.xx, why?