Wiki Page: 03. Displacement of piping with soil properties is very large, as if the soil properties are not considered during the analysis, why?

$
0
0
Applies To Product(s): AutoPIPE Version(s): 2004, XM, V8i Environment: N/A Area: Subarea: Original Author: Bentley Technical Support Group Date Logged & Current Version Feb. 2015 09.06.01.10 Problem: Displacement of piping with soil properties is very large, as if the soil properties are not considered during the analysis, why? Answer: There are 2 things to check that would cause this issue. Check #1: Soil Properties Be sure to check soil properties dialog to ensure that the all 16 values used are > 0.00. If so, enter a value > 0.00 and re-run the analysis Check #2: Static Analsysi Set - Soil Stiffness With AutoPIPE V8i 09.06.00.xx and higher, confirm the Static Analysis set dialog screen, Soil Stiffness is Set to Low, High, or Avg. See AutoPIPE online help for details on this setting. See Also Bentley AutoPIPE External Links Bentley Technical Support KnowledgeBase Bentley LEARN Server Comments or Corrections? Bentley's Technical Support Group requests that you please submit any comments you have on this Wiki article to the "Comments" area below. THANK YOU! Displacement of piping with soil properties is very large, as if the soil properties are not considered during the analysis, why?