Forum Post: RE: Thermal expansion

$
0
0
Hello Quique0185, After setting the anchors to flexible, what stiffness value did you use for all 6 stiffness values? or was the anchor set to Flexible but the actual stiffness values were still set to Rigid? It sounds as if there is something missing in your modeling of the piping system in AutoPIPE that does not match the as-built conditions. Do you have any tangible data from the system in operation that can be matched up to the model for verification of the AutoPIPE model to As-built conditions. Regards, Mike Dattilio Bentley TSG Support Analyst ===================================================