These are connecting nodes (not physical nodes) for following purposes:

Report loads at a vessel or equipment nozzle: Equivalent in AutoPIPE to a Reference Point. This is a better solution allowing either loads and allowable limits (e.g. from manufacturer) to be reported in a global or local direction. Local is very useful for skewed piping. A reference point can be assigned to any point in the model.

  1. Select Insert > Xtra data > Reference point...

Connect a support from one node to another:

  1. Select a point .
  2. Select Modify > Support ... The support dialog opens.
  3. Type the connection node in the Connected to: field.

 

 

See Also