Applies To Product(s): AutoPIPE Version(s): 2004, XM, V8i Environment: N/A Area: Reports Subarea: Original Author: Bentley Technical Support Group Date Logged & Current Version Feb. 2015 09.06.01.10 Problem: Since the fatigue data is tabulated such that at the highest tabulated stress, 10 cycles are allowed, what AutoPIPE will do if the upper tabulated stress is exceeded. So what does AutoPIPE do at the low cycle end of the curve? Answer: If the calculated stress value exceeds Maximum stress from fatigue curve, AutoPIPE will return number of cycles as 1 See Also Bentley AutoPIPE External Links Bentley Technical Support KnowledgeBase Bentley LEARN Server Comments or Corrections? Bentley's Technical Support Group requests that you please submit any comments you have on this Wiki article to the "Comments" area below. THANK YOU!