Applies To Product(s): AutoPIPE Version(s): 2004, XM, V8i Environment: N/A Area: Results Subarea: Original Author: Bentley Technical Support Group Date Logged & Current Version Mar. 2015 09.06.01.10 Problem: Why does the AutoPIPE Time History output report results not coincide with "Time History Post Processor" results? "how does AutoPIPE determine which time history forces and moments to use for stresses?" Maybe my question would be clearer with an example. See the plot below. Clearly, the max and min points are 226 and 340 N*m. Now look at the forces and moments output report below--the moment is reported as +395 and -395, depending on which side of the point. It's unnerving that AutoPIPE would report different results in different places. This is at a support (damper), and I have the ZPA option checked. Is AutoPIPE applying some sort of correction at this location, a correction that isn't shown in the time history post-processor? Answer: From the AutoPIPE help on this dialog see the last line: Time History results do not include ZPA corrections. Therefore if your time history analysis had ZPA option enabled, then NO the results on this dialog would Not match the output report. See Also Bentley AutoPIPE External Links Bentley Technical Support KnowledgeBase Bentley LEARN Server Comments or Corrections? Bentley's Technical Support Group requests that you please submit any comments you have on this Wiki article to the "Comments" area below. THANK YOU!
↧