Wiki Page: W726-94: Zero weight valve found at point warning message in AutoPIPE

$
0
0
Applies To Product(s): AutoPIPE, Version(s): 2004, XM, & V8i Environment: N/A Area: Warnings Subarea: Original Author: Bentley Technical Support Group Problem: The following is displayed in the model consistency check report: W726-94: Zero weight valve found at point How to fix? Answer: Open the offending valve dialog screen, or navigate to the Input grid, Valve tab: Notice that the indicated valve weight is missing. For all valve Ratings = NS (Non-Standard) user must manually update the weight field. Or Select a different Valve Rating that will then retrieve the information from the valve library if available. See Also Bentley AutoPIPE External Links Bentley Technical Support KnowledgeBase Bentley LEARN Server Comments or Corrections? Bentley's Technical Support Group requests that you please submit any comments you have on this Wiki article to the "Comments" area below. THANK YOU!