Quantcast
Channel: AutoPIPE
Viewing all articles
Browse latest Browse all 16073

Wiki Page: Warnings Messages displayed in AutoPIPE

$
0
0
Applies To Product(s): AutoPIPE, Version(s): 2004, XM, & V8i Environment: N/A Area: Warning Subarea: Original Author: Bentley Technical Support Group W21-38: This function cannot be applied at the current point. W31-86: No allowable stresses are available for the selected material in the material library W41-27: Parameters are outside the applicable range W79-85: 0 Stiffness in direction of imposed harmonic load. at XXX W97-213: Corroded thickness is required for sustained stress in B31.3 W726-2: Gap orientation has changed for guide at point XXX W726-6: Near zero length element at point XXX W726-7: Pipe diameter change without a reducer at point XXX W726-8: Kink in straight run of 90.0 deg at point XXX W726-8: Kink in straight run of 179.9 deg at point XXX W726-14: No anchors in current system W726-38: Allowable at ambient is outside of temperature range at point XXX for material YYYY W726-39: Allowable at XX is outside of temperature range at point XXX for material XXXX W726-93: Zero weight flange found at point XXX W726-94: Zero weight valve found at point XXX W726-110: Not all gaps are non-zero for following support(s) W726-170:The tee at point A04 has only two legs defined which may not meet the conditions to apply the equations for SIF and other stress indices. W726-195:Support D10 1-Zero length from 'supported' to 'connected' point W727-2: Temperature is outside the range specified the code for Expansion for AutoPIPE W727-3: Temperature is outside the range specified by the code for allowable W754-1: Sweep angle is 180 degrees W774-47 One or more combinations are set to none W801-14: No frequency below cutoff value W801-58: Smallest timestep for xxxx .TIH file = .... W831-11: Seismic level includes cases not analyzed W2014-35: Previous "to" must be the same as current "from" point. warning message in AutoPIPE W2018-11, W2018-12, W2018-16: Not authorized for ???? edition, AutoPIPE reverts to DEMO mode W2143-37:Extremely high value for Displacement tolerance > 1000 detected in loadset W2143-76:Friction scale factor is zero. Friction at all supports will be ignored for following analysis set W2143-121 Sc > 20 ksi (138 MPa). In calculation Sc will be set to 20 ksi (138 MPa) for expansion allow for pipe(s) in AutoPIPE W2143-123 Sh > 20 ksi (138 MPa). In calculation Sh will be set to 20 ksi (138 MPa) for expansion allow at following point(s)in AutoPIPE W2164-12:System contains Gaps/Friction/Soil data. Please enable non-linear option in the following Analysis sets

Viewing all articles
Browse latest Browse all 16073

Trending Articles



<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>