Applies To Product(s): AutoPIPE Version(s): 2004, XM, V8i Environment: N/A Area: Subarea: Original Author: Bentley Technical Support Group Date Logged & Current Version April. 2015 09.06.01.11 Problem: The following Appears in the Status window of the AutoPIPE PCF translator when importing a file: Conversion Started... Incorrect component connection tolerance Value Parsing..... Conversion Aborted.. Why and How to Avoid? Answer: The problem is that the program is not able to read the tolerance setting in the PCFIN.MAP file. Close AutoPIPE. The AutoPIPE PCF translator is trying to read the PCFIN.Map file typically found in the following file location: C:\ Bentley\ AutoPIPE Translators\ PCF Translator\ pcfin.map This file can be opened by any text editor (Ms WORD, Ultra Edit, notePad, etc..). Depending on program version and default file, there is a Tolerance Setting found on line 628 (again, subject to change), shown below: If this setting was found to be 0.000, or other small vales, change this value to be as shown above (starting in column 24), 1.000000. and save the file. If you are unable to save the file because of write protection, there may be a permissions issue where the user is not currently logged in with ADMIN rights to this folder. Remember the user needs to have complete Read / Write to the following folders and all sub-folders within: C:\Bentley C:\ Users\ username \ AppData\ Local\ Temp Be sure that the user has the correct permissions and the value of this setting is as indicated above before continuing. With this file saved and the tolerance confirmed, try to import the PCF file again. The fie should import without issue. See Also Bentley AutoPIPE External Links Bentley Technical Support KnowledgeBase Bentley LEARN Server Comments or Corrections? Bentley's Technical Support Group requests that you please submit any comments you have on this Wiki article to the "Comments" area below. THANK YOU!
↧