Wiki Page: 04. Added concentrated weight does not affect my displacement results in AutoPIPE, why?

$
0
0
Applies To Product(s): AutoPIPE Version(s): 2004, XM, V8i Environment: N/A Area: Subarea: Original Author: Bentley Technical Support Group Date Logged & Current Version April. 2015 09.06.02.06 Problem: Added weight does not affect my displacement results in AutoPIPE, why? Answer: Check the load case that the weight was assigned to: As seen above the load case was set to U140 and U1. No check to be sure that these load cases are being analyzed as part of an analysis set: In addition, verify that the load case is part of a combination that is displayed and printed on the Load Combination Dialog Load Cases Tab and Non-Code Combination tab, indicated bellow: If a specific indicated load case (ie. U1 or U140) is not part of an Analysis Set that is analyzed AND not indicated on the Non-Code Combination tab, then the concentrated load is not being considered. Fix, adjust the Analysis Set and Non-combination settings accordingly: See Also Bentley AutoPIPE External Links Bentley Technical Support KnowledgeBase Bentley LEARN Server Comments or Corrections? Bentley's Technical Support Group requests that you please submit any comments you have on this Wiki article to the "Comments" area below. THANK YOU!