Applies To Product(s): AutoPIPE, Version(s): 2004, XM, & V8i Environment: N/A Area: Warning Subarea: Original Author: Bentley Technical Support Group Problem: The following warning appears when running a Time History analysis: --------------------------- Warning --------------------------- W801-58: Smallest timestep for TPCE07 .TIH file = .000617 change the following: Analysis Steps (s) = from Automatic to value smaller than mentioned in warning message, ex. 0.00061 sec Output Steps (s) = from Automatic to value smaller than mentioned in warning message, ex. 0.00061 sec Run the analysis, remember it may take a bit of time to process, the application may appear to have stopped, just leave the mouse and keyboard alone until analysis is finished. See Also Bentley AutoPIPE External Links Bentley Technical Support KnowledgeBase Bentley LEARN Server Comments or Corrections? Bentley's Technical Support Group requests that you please submit any comments you have on this Wiki article to the "Comments" area below. THANK YOU!
↧