- Question:
AutoPipe Results> Code stresses floating dialog shows the Max Expansion Stress to be 4785 psi on the screen however, the report shows 2 stresses (+ /- side) for that node point, one of which has a higher stress of 5004 psi ?
Answer:
The CAE development team has confirmed there is a problem on the floating results dialog for displaying the highest value stress between +/- side (up stream / Down stream) of a node point for bend mid point . The output report and results grids are correct.
This has been loged under CAE-TR-11039.