Wiki Page: i. Why does AutoPIPE provide an option to “Ignore friction GR” on the Nonlinear analysis dialog?

$
0
0
Applies To Product(s): AutoPIPE Version(s): 2004, XM, V8i Environment: N/A Area: Analyze Subarea: Original Author: Bentley Technical Support Group Date Logged & Current Version Sept. 2015 09.06.02.06 Problem: Why does AutoPIPE provide an option to “Ignore friction GR” on the Nonlinear analysis dialog? Answer: As mentioned in AutoPIPE help: "Effect of friction on gravity movement cannot be accurately defined since the movement depends on the initial pipe placement. Ignoring friction would be equivalent to lifting the pipe to release the normal forces causing friction and then placing the pipe again on the support. The default is to ignore friction for gravity load." See Also 06. Non-linear Load Sequencing Explained Bentley AutoPIPE External Links Bentley Technical Support KnowledgeBase Bentley LEARN Server Comments or Corrections? Bentley's Technical Support Group requests that you please submit any comments you have on this Wiki article to the "Comments" area below. THANK YOU!