- How to manage the baffle spacing of a heat exchanger?
Answer: In the "Shell and Tube Heat Exchanger Properties" window go to the "Bundle" tab.
The baffle spacing can be adjusted in one of 2 ways by making the appropriate selection in the area "Baffles/Support Plates", :
a) enter the baffle spacing in the "Spacing" field or
b) enter the number of baffles in the "Quantity" field.