Wiki Page: Flange Analysis - AutoPIPE

$
0
0


Topics under the heading should be based on Flange Analysis

  1.  See the following link for logged enhancements: Flange Analysis Enhancements for AutoPIPE

  2. On the Load tab, Operating Pressure field is limited to 3000 psi. Why?

    Answer:  In AutoPIPE V8i 09.05.xx.xx and lower, there is an internal limitation of 3000 psi for data entry. A new enhancement (CAE-CR-11051) has been logged to increase this limitation.

  3. Flange Check report does not show results on a consistent and repeatable basis it is found to be blank. Toggling the Analysis Methods back and forth between ASME or ANSI does nothing to help the matter reports are still found to be blank. Why does this happen and how to fix it?

    Answer: The CAE development team have fully investigated the problem and after rigorous testing were able to repeat the problem on one machine. The problem may arise due to memory overwrite. Please perform if you are using AutoPIPE V8i version v9.5.0.21.

    Please log a service ticket siting this information (Problem # 93986).

     