The following Wind enhancements have been logged for inclusion into a future version of AutoPIPE: Note: if an enhancement has not been added to the program, log an Service request for that enhancement. The more requests logged per an enhancement, the quicker the CAE development team will add that feature to the program. Defect 203815: "All segments exposed to wind" checkbox on Wind dialog is not synchronized with the "Apply wind" checkbox of Segment tab Description: Under Wind Profile (Height and Wind Pressure), suggest to increase from maximum eight (8) sets of data to at least ten (10) sets of data to capture larger range of available data . Steps to repeat: 1. Open Walkthru model 2. Open the Segment tab of Review Component Data dialog and uncheck "Apply wind" for all segments 3. Open the Wind load dialog Observe that "All segments exposed to wind" checkbox is unchecked. 4. Enable the "All segments exposed to win" checkbox and pres OK on the Wind dialog 5. Open the Segment tab of Review Component Data grid Note that the Apply Wind checkbox for all the segments are still unchecked. Development Project: 10.00.xx Enhancement 140470: Add IBC 2009 to the wind profiles Description: Add IBC 2009 to the wind profiles Development Project: TBD Defect 139097:Tracker#:11097 Ground Elevation for Wind Dialog entered in Feet only for all input units Description: The Ground Elevation for Wind is always entered in Feet, regardless of the model units selected in General Model Options Dialog. Avoidance: Always convert Ground Elevation for Wind to Feet before entering on the Wind dialog Development Project: 9.6.0.19 Enhancement 138668: Increase height-pressure data pairs for the wind profile to 10 or more Description: Under Wind Profile (Height and Wind Pressure), suggest to increase from maximum eight (8) sets of data to at least ten (10) sets of data to capture larger range of available data . Development Project: 9.6.0.19 Enhancement 138198: Add option to set friction = 0 for non-linear analysis of Wind load cases Description: Add option to run non-linear analysis with friction = 0 for Wind load cases . Development Project: TBD Enhancement 137103: Add STAAD wind and seismic load generators Description : Add STAAD wind and seismic load generators which includes ASCE-7, 2002 and ASCE-7, 2010 codes. Development Project: 9.6.0.19 Enhancement 137023: Add input grid for wind loading Description: Add input grid for wind loading . Development Project: TBD. See Also Enhancements Requests and Logged Defects Bentley AutoPIPE
↧