702173 ASME Nuclear: Incorrect density, composition, and modulus values for standard pipe materials NI and GROUP-1-B 702082 ASME NC/ND: Stress Summary calculations incorrectly uses branch pressure and geometry for pressure term calculations 619540 ASME NB: Incorrect stress results may be reported for negative face of a reducer node that is directly connected to a tee branch 537789 ASME NB: Stress summary containing equation 10 transient with a user defined non-reversing SAM category combination may give incorrect results 407514 Material properties set for valve or flexible joint are used to calculate allowable stress for pipe that follows 372995 ASME NB thermal transient analysis gross discontinuity stress may be incorrectly calculated at locations involving last TTA pipe 331101 ASME NC/ND: C2r and C2b stress Indices may be incorrectly calculated for fillet welded and partial penetration welded branch connections 323304 ASME NC/ND: SIF value lower than 2.0 may be calculated when "Use SIF of 2.0" is checked 265109 JSME Class 2-PPC: B1 stress index is incorrectly reported as 1.0 for a reducer with cone angle value of 30.0 263384 Stress indices of bend are incorrectly applied to reducer 242019 JSME Class 2-PPC: B1 stress index is incorrectly reported as 0.5 for a reducer with cone angle value of 60.0 224470 JSME Class 2-PPC: Maximum applicable B1 and B2 indices value at a point may not be used 224452 JSME Class 2-PPC: B1 and B2 indices reported at valve far point are incorrect for valves that are not butt welded 181952 Tees with different material across tee legs may report inconsistent allowable values 179635 ASME NC/ND: Elbows with any flange type reports B1 factor for socket welding flange 177864 For ASME NC/ND, Reducers at Cone Angle 30 deg Reporting Wrong B1 Index 138755 SAM axial stress of plus face of a point uses axial force of minus face 138656 The allowable (K) factor does not reset after changing the stress category 138342 Ke is less than 1 when service level Rupture is selected and 2.4 Sm 1.0 for t < 0.237" and ASME NC/ND 2001 and later 135638 Moment summation incorrectly applied to reverse dynamic loads for NC 1972-1980 135637 Problem with tee run moment summation for unsigned SAM cases 135501 For ASME NB-1975 add, K2 and K3 indices are incorrect for Flush BW Transition 135482 TTA Pipe and Insulation grid blocks valid pipe thickness input for SI Units 135367 Stress level code combinations like (SUS) are ignored for ASME NB/NC/ND 135356 Reinforced tee B2b & B2r stress indices are set equal for NC/ND 2003-2004 code 135355 Code year NC/ND 1980 Summer is mislabeled as 1982a. Also ND 1983W is mislabeled 135309 Program incorrectly shows code check failing when equation 10 fails for ASME NB 135306 Moment summation at the tee for ASME NB ignores moment sign for second leg 135289 ASME NB 1977 K2 and K3 stress indices are incorrect for some welded transitions 135271 For vertical API610 pumps, stresses are NaN when AUTODIN is used 135248 New KHK2 models show zero results except for combinations with PW 135242 DeltaT1 and DeltaT2 units are not converted correctly when switching to SI units 135239 New KHK2 models show default combinations as those of KHK1 piping code 135238 Stress at pipe end of far reducer point with a support has zero moment 135204 Pipe side SIF at far point of reducer may not be correct 135203 Butt Weld offset or mismatch is incorrectly used as offset ratio delta/t in SIF 135187 For ASME NC/ND 1986-1989 Girth Butt Weld SIF is set to 2.8 for t < 0.237 inches 135110 Pressure & allowable stresses can be incorrect for multiple analysis sets 135109 JSME: Cannot add load cases to combination in CS1(P+S) category 134441 Sustained stress adds up all P cases when multiple analysis sets are defined 134440 TTA profiles with long transients may return incorrect Delta T1 & T2 values 134435 Cannot enter a User B1 value of less than 0.5 for ASME NB 134434 Selecting load case in the Impose Disp. dialog always displays E49-40 for KHK 134426 Member static earthquake factor is not applied correctly at valve midpoint 134412 FY allowable force resets to 'none' for all reference point data 134411 Comb based on last analysis set only are correct in General Stress report 134326 Incorrect NC/ND reversing loads in Service Levels C & D for rotated tees 134325 Incorrect JSME moment summation for rotated tees 134323 Support dlg: Switch 'Constant' support (designed) to 'Spring' crashes program 134322 Valve with midpoint is exported incorrectly as a valve and run pipe to STAAD 134208 Incorrect ASME NB moment summation for rotated tees 129663 Stress indices and B2 correction factor for reducers may be calculated incorrectly 123586 Stress indices and moment of inertia may be calculated incorrectly for nodes with transition welds See Also Critical and High issues Bentley AutoPIPE
↧