      Applies To        Product(s): AutoPIPE Vessel   Version(s):   Environment:  N/A   Area:    Subarea:  N/A   Original Author: Sudip Ganguly, Bentley Technical Support Group                   1. Problem Description Why do I get the  error message "the results file cannot be written to" when I run the "strength calculations"? Reason It is probably because a report generated from a previous run is already open. Solution Close the report (the word document) that is already open and try running "strength calculations" again.   2. Problem Description I have selected APVessel as the design standard for bracket but the program is crashing, how do I resolve this issue? Reason The issue has been acknowledged and is under investigation. It will be fixed in future release of AutoPIPE Vessel. Solution Currently there is a workaround for this problem. Please see the following link for the solution: http://communities.bentley.com/products/pipe_stress_analysis/m/pipe_stress_analysis_gallery/269463.aspx   1. Problem Description How to resolve the following error message? “Design code required isn’t part of your license”   Solution Please see the following link: License resetting  