Wiki Page: 12. In AutoPIPE, what SIF is being used in the calculations: Automatic Code calculated SIF, User Defined SIF or other?

$
0
0
Applies To Product(s): AutoPIPE Version(s): ALL Environment: N/A Area: Model Input Original Author: Bentley Technical Support Group Date Logged & Current Version Mar. 2015 09.06.01.10 Problem: After inserting Xtra Data> Joint Type & User SIF> change to User Defined, and set the values for both in / out of plane SIF = 1.23 with Override all other SIF at this point checked on, the Bend data listing shows the code calculated value instead of my user SIF value at node point A01 F, why? Solution: This is by design, Bend data listing will show the code calculated SIF values. However, if a different SIF value was applied to a bend, the letter "u" is added directly after the value. As indicated at the bottom of the report, u = User sif present at the point, check user-SIF data listing. In addition, reviewing the code compliance report shows: See Also Bentley AutoPIPE