Applies To Product(s): AutoPIPE, Version(s): All Area: Load-case Original Author: Bentley Technical Support Group Nov 2014, AutoPIPE V8i 09.06.01.10 Problem: How to perform a Pressure analysis in AutoPIPE? Solution: AutoPIPE performs a pressure analysis when the following settings are enabled: Load> Static Analysis sets> select and modify any analysis set> Enable the check-box to the left of "Calculate pressure extension cases, e.g. P1, P2, etc" as shown below: Please see the online help for details on this option / setting. See Also "Pressure" - AutoPIPE load case Bentley AutoPIPE
↧