Forum Post: RE: Why limit "Pipe ID" length to be 8 letters? This is troublesome for large piping system.

$
0
0
This has been an issue for me as well quite some time now. Linenumbers though can be inserted under the Segment tab in the Input Grid window, but it requires you to understand how AutoPIPE deals with this. Nevertheless, more than 8 characters would make sense

Wiki Page: "Error" messages in AutoPIPE Vessel

$
0
0
Comments, Questions, and Answers related to Error Messages in AutoPIPE Vessel E xecuting Strength Calculation Error messages Fail to open DGN file - Error Code = 77832, Error!!! Abnormal Termination message appears when starting program Error Message Number: 27 Tubesheet Loading condition, longitudinal membrane stress 98 GEOMETRY : Unable to design geometrical plate layout without interference 151 License: Design Code required isn't part of your license (ASME) 181 Cone 3: should be placed between 2 shells 235 Floating Head (split ring): allowable stress at temperature missing (240 Deg C)\ 236 Floating Head (split ring): ambient allowable stress missing 237 Floating Head (split ring): exceptional ambient allowable stress missing 287 FLANGES: error in formula [40*bd] for gasket according to AD B7 316 LOCAL LOADS ((Support)): PD 5500 Figure G.2.2-18 deflections of cyl. shells due to radial loads, values beyond curve boundaries 334 Tubesheet: Design code required ins't part of your License (ASME) 411 & 412, Nozzle AP (pad) allowable stress at temp missing, exceptional ambient allowable stress missing 425 FLOATING HEAD (split ring/splices): insufficient thickness or gap not maintained 593 Saddle effective angle < 30Deg (blast int Max P) (Corroded inertias) (Corroded Weight), revise design of vessel 885 Tubesheet: tubesheets gasketed with shell are not possible for a fixed tubesheets heat exchanger See Also Warning Messages, Unregistered Messages, Error Messages, or Application Crash issues Bentley AutoPIPE Vessel

Wiki Page: Q. 27 Tubesheet Loading condition, longitudinal membrane stress.. message appears in AutoPIPE Vessel

$
0
0
Applies To Product(s): AutoPIPE Vessel Version(s): ALL Area: Errors Date Logged & Current Version March 2018 40.06.00.07 Problem: What to do to avoid the error in the floating head design 27 Tubesheet loading conditions, longitudinal membrane stress Solution: There is failure due to tube axial membrane stress, the tubes would buckle: Increasing tube thickness (ex. 5.156 mm) helps remove all of the tube membrane stress errors but that might not be a solution from process/thermal design perspective as tube becomes too thick: Another solution could be to reduce baffle spacing (example - reducing the spacing to 300 mm) . Overall it really depends on what approach the designer wants to adopt. See Also AutoPIPE Vessel Error messages

Wiki Page: Q. 885 Tubesheet: tubesheets gasketed with shell are not possible for a fixed tubesheets heat exchanger... message in AutoPIPE Vessel

$
0
0
Applies To Product(s): AutoPIPE Vessel Version(s): ALL Area: Date Logged & Current Version April 2019 41.00.00.006 Problem: The following is displayed when I run the application: Errors: 885 Tubesheet: tubesheets gasketed with shell are not possible for a fixed tubesheets heat exchanger How to resolve? Solution: There is a detailed in section C7.5 of CODAP Division 2 (Edition 2010) dedicated to Fixed tube sheet exchanger and Alternative rules; wherein configuration 'd' covers tube sheet gasketed on both sides, clamped between flanges. However at this time, April 2019, AutoPIPE Vessel does not have the ability to model this type of configuration. A new enhancement (1021806) has been logged and should be added to a future version of the program. If you have this issue, please log a Service Request, referencing this WIKI and asking if this modeling approach has been added to the program. See Also AutoPIPE Vessel Error messages

Wiki Page: 12. Modeling Approach - AutoPIPE Nozzle

$
0
0
Item 01: Can AutoPIPE Nozzle be used to model a support on an elbow? See Also Table Of Contents - AutoPIPE Nozzle Wiki page Bentley AutoPIPE

Wiki Page: 01. Can AutoPIPE Nozzle be used to model a support on an elbow?

$
0
0
Applies To Product(s): AutoPIPE Nozzle Version(s): V8i Area: Modeling Original Author: Bentley Technical Support Group Date Logged & Current Version Mar. 2016 08.11.08.26 Problem: Can AutoPIPE Nozzle be used to model a support on an elbow? Solution: AutoPIPE Nozzle does not have a shell type = elbow. However, AutoPIPE nozzle does have a shell type = Cylinder, where a trunnion can be modeled atop it. Suggest this as an approximation approach for an elbow with a trunnion. To get an exact answer would require modeling in a full FEA program. See Also Modeling Approach - AutoPIPE Nozzle Bentley AutoPIPE

Wiki Page: 01. Installation - AutoPIPE Nozzle

$
0
0
Applies To Product(s): AutoPIPE, Version(s): 2004, XM, & V8i Area: Installation Original Author: Bentley Technical Support Group Comments, Questions, and Answers about installing AutoPIPE Nozzle: Item #1: Bentley AutoPIPE Nozzle Release Notes Item #2: How to download and install AutoPIPE Nozzle? Answer : AutoPIPE Nozzle 08.11.07.19 and lower can be downloaded from the Bentley Website and installed like any other Bentley application. However, newer versions of AutoPIPE Nozzle have been integrated into the installer of AutoPIPE. Another words, it is an option to install during installation of AutoPIPE V8i 09.05.xx.xx and higher. This option is by default checked ON, but can be unchecked as desired to prevent the application from being installed. Only if it was unchecked would the application not be installed with AutoPIPE. Item #3: How to install AutoPIPE Nozzle 08.11.08.xx and higher if the installation option to install was unchecked during installation of AutoPIPE V8i? Answer : Uninstall AutoPIPE V8i, and re-install AutoPIPE V8i confirming AutoPIPE Nozzle option is checked ON to be installed also (see image above). After the installation is complete, verify it has been installed by selecting Start> All Programs> Bentley Engineering> AutoPIPE Nozzle V8i should now be listed, open the folder and start the program as desired. Item #4: How much does it cost to upgrade? Answer: Select here See Also Table Of Contents Bentley AutoPIPE

Wiki Page: 13. Graphics issues reported in AutoPIPE Nozzle

$
0
0
Applies To Product(s): AutoPIPE Nozzle Version(s): ALL Area: Graphics Date Logged & Current Version March 2018 08.011.08.31 Problem: After installing, licensing, and starting the program, the tab names are set to Tab1, Tab2, and Tab 3 instead of the normal tab names as shown below Why and how to fix it? Solution: In this case, the application was installed on Windows 7, 32 bit) where WinNozl 2.0 had already been installed and then AutoPIPE Nozzle was installed at the same time. Workaround Remove all previous WinNozl and AutoPIPE Nozzle applications from the computer and then install the latest version. See Also Table of Contents Bentley LEARN Server

Wiki Page: 14. Library issues reported in AutoPIPE Nozzle

$
0
0
1. Material selection is missing information See Also Table of Contents Bentley LEARN Server

Wiki Page: A-03. Missing material library file warning message in AutoPIPE Nozzle

$
0
0
Applies To Product(s): AutoPIPE Nozzle Version(s): V8i Area: Warning Original Author: Bentley Technical Support Group Date Logged & Current Version May. 2016 10.01.00.09 Problem: The following message appears when using selecting a material --------------------------- Warning --------------------------- Missing material library file --------------------------- OK --------------------------- Why and how to avoid it? Solution: Open AutoPIPE Nozzle's program folder: C:\Program Files (x86)\Bentley\AutoPIPE Nozzle V8i Confirm that ASME2.bin file is located in the folder? This file was missing from AutoPIPE Nozzle AutoPIPE 08.11.08.23 & 08.11.08.26 which were installed with AutoPIPE V8i 09.06.01.10 to AutopIPE CONNECT 10.01.00.09. Workaround: There are 2 methods to resolve this issue: 1. Request Library file from technical support Submit a Bentley Service request referencing this WIKI and asking for this missing library file. After receiving the file, copy it to the AutoPIPE Nozzle folder: C:\Program Files (x86)\Bentley\AutoPIPE Nozzle V8i And, restart the program. 2. Upgrade Upgrade your version of AutoPIPE to install a newer version of AutoPIPE Nozzle that does not have this issue. See Also Warnings, Errors, Crashed, Confirm Messages in AutoPIPE Nozzle Bentley AutoPIPE

Wiki Page: _A_ Table Of Contents - AutoPIPE Nozzle Wiki page

$
0
0
Table Of Contents Installation Release Notes License How to License License status = Expired on the Activation Status tab of LMT, why? Printing Program Tabs - Shell Tab Nozzle Tab Reinf. Pad Tab - under construction Geometry Tab - under construction Load Tab Factors Tab - under construction System Tab Importing Nozzle Loads from AutoPIPE Examples - Tutorial Structural Newsletter Warnings, Errors, Crashed, Confirm Messages Results Known Enhancements / Defects Modeling Approach Graphics Library See Also Bentley AutoPIPE

Wiki Page: Q. "Your user account does not have write access in the AutoPIPE program folder"..... message appears when installing AutoPIPE, why?

$
0
0
Applies To Product(s): AutoPIPE Version(s): ALL; Area: Installation Original Author: Bentley Technical Support Group Date Logged & Current Version Jan. 2017 10.01.00.09 Problem: The following message appears when installing AutoPIPE: Your user account does not have write access in the Autopipe program folder..... Then installation stops. Why? and how to avoid? Solution: First be sure that the user logged on when installing has full admin rights. Installing AutoPIPE CONNECT 10.01.xx.xx: Perform the following procedure: 1. Can you please check that AutoPIPE program data folder is created for that user? ex. Folder path for version 10.1.0.8 is “ %programdata%\Bentley\AutoPIPE CONNECT ”. 2. Does the folder exist, if yes go to step #3. If NO, this folder doesn’t exist, then most probably it is user rights issue. Again confirm that user currently logged on has admin rights to the computer. 3. If Yes, this folder exists, then create an empty file in a specific location by using the following steps: a. Open Notepad b. Select File > Save i. Folder location (create folder as needed) = “%programdata%\ Bentley\ AutoPIPE CONNECT\ ii. File name = AUTOPIPE.DBG” c. Click Save. d. Run AutoPIPE. 4. What happens? Will the application now open? If Yes, great continue using the program If No, go to next step. 5. File a Bentley Service request mentioning this WIKI and include the results of the above efforts See Also Errors that occur when Installing / Uninstalling Bentley AutoPIPE

Wiki Page: Bentley AutoPIPE - Japanese version

$
0
0
AutoPIPE version available in this language: AutoPIPE CONNECT v.12.00.00.14 Released April 17, 2019 Notes: 1. More information available by clicking here AutoPIPE CONNECT v.10.01.00.08 Released June 15, 2016 Notes: 1. More information available by clicking here AutoPIPE CONNECT v.10.00.00.10 Released January 29, 2016 Product Name: Bentley AutoPIPE V8i Version Number: 10.00.00.10 Application Group: SELECT Documentation & Tutorials Language: Japanese Solution: Pipe Stress Analysis Operating Systems: Windows 7 Windows 7 x64 Windows 8 Windows 8 x64 Windows 10 Windows 10 x64 Notes: 1. More information available by clicking here AutoPIPE V8i SS5 v.09.06.02.06 Released July, 7, 2015 Product Name: Bentley AutoPIPE V8i Version Number: 09.06.02.06 Application Group: SELECT Released Products Language: Japanese Solution: Pipe Stress Analysis Operating Systems: Windows 7 Windows 7 x64 Windows 8 Windows 8 x64 Notes: 1. More information available by clicking here AutoPIPE V8i SS5 v.09.06.01.11 Released January 27, 2015 Product Name: Bentley AutoPIPE V8i Version Number: 09.06.01.11 Application Group: SELECT Released Products Language: Japanese Solution: Pipe Stress Analysis Operating Systems: Windows 7 Windows 7 x64 Windows 8 Windows 8 x64 Notes: 1. More information available by clicking here 2. Select link here for download, installation, and licensing documentation in native language. AutoPIPE V8i SS4 v.09.05.01 Released September 26, 2013 Product Name: Bentley AutoPIPE V8i Install Guide - Japanese Version Number : 09.05.01.05 Application Group: SELECT Documentation &Tutorials Language : Japanese Solution: Pipe Stress Analysis Operating Systems: Windows XP Windows Vista Windows Vista x64 Windows XP x64 Windows 7 Windows 7 x64 Notes: 1. More information available by clicking here AutoPIPE V8i SS4 v.09.05.01.02 Released July 23, 2013 Product Name: Bentley AutoPIPE V8i Install Guide - Japanese Version Number: 09.05.01.02 Application Group: SELECT Documentation & Tutorials Language: Japanese Solution: Pipe Stress Analysis Operating Systems: Windows XP Windows Vista Windows Vista x64 Windows XP x64 Windows 7 Windows 7 x64 AutoPIPE V8i SS2 v.09.04.00 Released June 15, 2012

Wiki Page: AutoPIPE CONNECT Release Notes (12.00.00.14)

$
0
0
Product Version Product Bentley AutoPIPE CONNECT Version v12.00.00.14 Language English Date Posted English - Jan 2019 Japanese - April 2019 Platforms Microsoft Windows 7 Professional or higher (with Service Pack 1) Microsoft Windows 8 Professional or higher Microsoft Windows 8.1 Professional or higher (with KB2919355 Update) Microsoft Windows 10 Professional or higher 32 or 64 bit OS .NET Framework 3.5 SP1 4.6.1 Licensing Uses CONNECT Licensing OPIM Does not support OPIM 10.0 - 10.2 Suggest to install default version 08.11.11.294 Or, update to OPIM 10.03.00.19 or higher Description: Bentley AutoPIPE CONNECT Edition v12 (v12.00.00.14) - English Bentley AutoPIPE CONNECT Edition is a stand-alone, engineering application for the calculation of piping stresses, fatigue stresses, fluid transient, bowing or thermal transient analysis, flange or pipe support design, and equipment nozzle loading analysis under static and dynamic loading conditions. In addition to 30+ piping codes, AutoPIPE incorporates ASME, JSME, British Standard, European, API, NEMA, ANSI, ASCE, AISC, UBC, GOST and WRC guidelines and design limits to provide a comprehensive analysis of the entire system. This new release provides new features, critical code updates, and enhanced product interoperability. This is a product generation update for AutoPIPE CONNECT (v11.03.00.08) which includes several bug fixes plus the following new features: What is New & Changed in AutoPIPE The following outline identifies new features and enhancements in the AutoPIPE CONNECT Edition version 12.0.. General CONNECT Licensing This product version utilizes CONNECT Licensing, which is not supported by SELECT activation key(s). CONNECT Licensing features new behavior to enhance your organization's user administration and security with mandatory user sign-in via CONNECTION Client to access the application. If you are already signed in to the CONNECTION Client, you have met this prerequisite. If you have not, please refer to the Administrator's Resource Center and/or contact your administrator for assistance in the registration and sign-in process. Increased the number of entries listed in the recent model list for a better user experience. Support/Reference IDs are now auto-generated and read-only for better tracking of supports. Piping Codes Added ASME BPVC Section III 2017 code for the construction of Nuclear Facility Components. Analysis Added Upheaval Buckling Analysis to perform a simplified buckling analysis based on idealized pipeline imperfections in long buried pipelines. [ Technology Preview ] Added the NodeLink feature to allow a node to be connected to another piping node. This allows for the release of connectivity in a specific direction to be utilized in hanger selection where an Anchor is not present. Anchors can now be defined as connected to a structure node to allow the anchor load to be resolved into the structure. Added Support Optimization to determine optimal support locations and options based on criteria such as supporting structure loads, allowable displacements, and support costs. [ Technology Preview ] Reports Added a Select All option on the result grid to conveniently select/un-select all combinations at one time. Input and output reports 1 are now available in the SQLite DB format. Post-processing, review, and print functions are now possible in third-party applications and report generators. Stress reports have been improved when utilizing DNV-OS-F101 by changing the title "Comb. stress category" to "Load Control Limit Check". Import Added an option to import E3d (*.pcf) files via the PCF Translator. Interoperability Two-way interoperability between SACS and AutoPIPE has been improved, including change management by using Structural Synchronizer (aka ISM). [ Technology Preview ] Integration with OpenPlant Isometrics Manager CONNECT Edition has been implemented for stress isometrics. Hidden segments in a model are no longer exported to isometric drawings in OpenPlant Isometric Manager. Security Release Notes Not applicable to this release. 1 The Version 6.1 Point Data Listing, Extended Component Data Listing, Flange Analysis Report, and Thermal Transient Analysis Report are not available in the SQLite DB format. This feature will be made available in a future release. Technology Previews - Provide users preliminary access to features currently in development but not yet ready for production. These features are provided at no additional charge to promote awareness of a feature or technology to be deployed in a future release. Users are encouraged to provide feedback and suggestions. Now all Technology previews are available in the application. These commands have '[Technology Preview]' displayed in the tool tip. Detailed Readme: English Note: 1. Readme file contains limited amount of information about errors / enhancements, only QA&R members have access to detailed Error Reports Download, Install, and License Procedure: See procedure here Installed with AutoPIPE: Bentley ADLPipe to AutoPIPE Translator 01.00.00.22 Bentley AutoPIPE Batch Generator 01.00.00.04 Bentley AutoPIPE CONNECT v12 12.00.00.14 Bentley AutoPIPE CONNECT v12 Setup 12.00.00.14 Bentley AutoPIPE Nozzle V8i 08.11.08.35 AutoPIPE Preview Handler 01.01.05.00 Bentley PCF to AutoPIPE Translator 01.00.00.74 Bentley STRAIT to AutoPIPE Translator 06.00.00.15 Connection Client 10.00.13.17 OPIM (OpenPlant Isometric Manager) 08.11.11.294 Validation Certificate: Program Name: AutoPIPE CONNECT Edition v.12.00 Revision or Version Number: v12.00.00.14 The above computer program has been validated by both manual and automated testing procedures as part of a comprehensive product test plan consisting of more than 700 verification and validation test cases. Software quality metrics are defined against a quality standard established by existing and historical commercial versions of the program. Bentley Systems, Inc. maintains a quality assurance program t hat controls the life cycle activities of this computer program for the design of nuclear safety related piping in compliance with ASME NQA-1-2008/ 2009a, 10 CFR Part 50 Appendix B, and 10 CFR Part 21 quality standards. Test plans and validation data are on file at Bentley's Walnut Creek, California, USA office. Support for this computer program is described in Bentley SELECT Program Agreement and includes 24/7 telephone, email, and web based support along with free upgrades and updates as they become available. See copy of Software Validation Certificate by starting AutoPIPE, select Help Ribbon, Software Validation certificate icon. See Also AutoPIPE CONNECT Release Notes (10.00.xx.xx - higher) How do I download, install, and license AutoPIPE? Bentley AutoPIPE

Wiki Page: 07. How to assign code allowable stress for hydrotest loading: hoop stress and HY stress combination in AutoPIPE?

$
0
0
Applies To Product(s): AutoPIPE Version(s): All Area: analysis Original Author: Bentley Technical Support Group Date Logged & Current Version May 2015 09.06.02.06 Problem: How to assign code allowable stress for hydrotest loading: hoop stress and HY stress combination in AutoPIPE? Solution: After creating the respective analysis sets, run a Static analysis, and open the Load Combinations dialog, as shown below: Currently all the combinations have a code allowable that calculated Automatically. However, a user defined value can be specified by Step #1: Unchecking the respective boxes in the Auto Update column, Step #2: Changing the Allowable (k) factor and / or Allowable Stress column values as needed. Press OK button to close the dialog and create an out put to review the results. See Also "Hydrotest" Bentley AutoPIPE

Wiki Page: "W88-24: Allowable based on cold yield Sy may be un-conservative" Bentley AutoPIPE message is displayed in the program?

$
0
0
Applies To Product(s): AutoPIPE Version(s): All Area: Message Original Author: Bentley Technical Support Group Date Logged & Current Version Aug. 2015 09.06.02.06 Problem: After selecting any option from the Test Temperature Case on the Hydrotest Drop down listing, the following warning is displayed: --------------------------- Bentley AutoPIPE --------------------------- W88-24: Allowable based on cold yield Sy may be un-conservative --------------------------- OK --------------------------- Why and How to avoid it? Solution: Please open Hydrotest load dialog: Press the Help button and select the hyperlink for " Temperature load case/ Factor " . Details of this message are mentioned there. Essentially the user should evaluate the Temperature load case selected to be sure if the calculated results are to be conservative or un-conservative. See Also "Hydrotest" - AutoPIPE Load Case "Bentley AutoPIPE" Messages Bentley AutoPIPE

Wiki Page: 08. How to calculate the Hydrotest Hoop stress and Allowable values in AutoPIPE?

$
0
0
Applies To Product(s): AutoPIPE Version(s): ALL; Area: Results Date Logged & Current Version Oct. 2018 11.04.00.10 Problem: How to calculate the Hydrotest Hoop stress and Allowable in AutoPIPE? Give the following information: Piping code = B31.3 - 2014 Ambient temp = 21 deg C Units = SI Hydrotest settings: Solution: Start by looking at the following AutoPIPE help section: 1. Help > Contents> Contents Tab> Reference Information> Code Compliance Calculations> select the proper piping code & year 2. Select the Hoop Stress section 3. Look for the appropriate equations for Stress and Allowable that AutoPIPE is using. From the Pipe properties dialog find values for Do, Wall thk, Corrosion allow, Mill tol, W, and E. From the Pressure Temp tab on the grids find the respective value for Pressure, Temperature, and SH as defined by the Hydrotest dialog (ex. P4 - T4) Perform the Calculations Stress Calculation: where: P = 4 N/mm^2 Do = 219.075 mm tred = 7.036-.1.5-0.879 (Help> Definition of terms> Pipe Properties) Y = 0.4 Hoop Stresses = 138.726 N/mm^2 Allowable calculation:: = W*E*SH where: W = 1 E = 1 SH = 137.8951 N/mm^2 Hoop Allowable = 137.90 N/mm^2 Compare to allowable documented for hydrotest case: Note: In some case the allowable is calculated as the lesser of ( W*E*SH, Cold Allowable) The hoop allowable matches exactly, however hoop stress hand calculation does not match AutoPIPE, why? Question: What else can influence the code calculations. Answer: Correct, the Results Model Options settings. If you do not already know about these settings, strongly suggest that you spend a little time getting to know them all because these settings will significantly affect your results. As in this case, the results calculation was changed because of "Use nom. thk for hoop" setting was enabled. Instead of Tred, use Tnom. in the hoop stress equation. Now, Hoop stress = 91.009 N/mm^2. See Also Assign user defined code allowable stress for hydrotest loading Hydrotest FAQ Bentley AutoPIPE

Wiki Page: 06. Why does the Hydrotest case show an Allowable K Factor of 0.9 in AutoPIPE?

$
0
0
Applies To Product(s): AutoPIPE, Version(s): All Area: Loads Original Author: Bentley Technical Support Group Dec 2014, AutoPIPE V8i 09.06.01.10 Problem: Why does the Hydrotest case show an Allowable K Factor of 0.9? Solution: Please see the following AutoPIPE help section: Help > Contents> Contents Tab> Bentley AutoPIPE> Command Reference> Load Commands> Hydrotest Loads see Notes section: See Also "Hydrotest" Bentley AutoPIPE

Wiki Page: 03. Where are the factors and values that are used in a Hydrotest load case located in AutoPIPE's output (report) file

$
0
0
Applies To Product(s): AutoPIPE Version(s): 2004, XM, V8i Area: Report Original Author: Bentley Technical Support Group Date Logged & Current Version Feb. 2015 09.06.01.10 Problem: I know that for HY calculation I must access the window Hydrotest where I select the pressure case (P1) and the multiplier (that is generally 1.5). I'm not able to see the value of the test pressure in output file How can see the value of test pressure in the output (report) file? Why the software doesn't show the value of multiplier as requested by ASME B31.3 (that is generally 1.5 Sc/Sh)? Solution: The Hydrotest parameters are printed in the " Analysis Summary " section of the output report under "Hydrotest Load" Temperature Load Case Factor Pressure load Case Factor Note: Temperature and Pressure load case values can vary from node point to node point. In some cases the values may be all the same, in other cases for each set of node points these values can be different. Therefore, AutoPIPE performs this calculation internally and prints the results in the output report. Each of the values (Press or Temp) used for the calculations are not printed in the output report. The following enhancements have been logged: TFS-E237988: Report calculated hydrotest pressure in model input listing. See Also Bentley AutoPIPE

Wiki Page: 02e. "Hydrotest" - AutoPIPE Load Case

$
0
0
The Load> Hydrotest command enables the user to define the hydrotest conditions of a piping system. A hydrotest is a common method for testing the integrity of a piping system before it is put into service. In this test, the piping system is filled with pressurized water and checked for leakage, etc. The Hydrotest option permits a simulation of this scenario. Please note that the AutoPIPE Hydrotest option automatically converts all spring hangers into rigid supports to simulate the holding pin which is still in the spring hanger during the hydrotest. Note: AutoPIPE 10.01.xx and higher, see the following AutoPIPE help section: Help > Contents> Contents Tab> Bentley AutoPIPE> Supplemental Documentation> on this page scroll down to see a hyperlink for " Hydrotest Tutorial " Comments, Questions, and Answers Item #1: V-stops are not allowing lateral movement during Item #2: Non-linear analysis method Item #3: Report: Hydrotest load case settings Item #4: High results values Item # 5: AutoPIPE V8i 09.06.01.10 and higher new hydro test method Item #6: Allowable K Factor = 0.9 Item #7: Allowable: user defined Item #8: Allowable value calculation Item #9 Please select a valid test pressure case for B31.3 test pressure update Item #10: Difference results between the Normal Sustain load (ex. Gr+MaxP (1)) and the Hydrotest Sustain load (ex. Gr+MaxP (2)) Item #11: Apply more than one hydro-test analysis sets Item #12: Hydrotest load are not applied on a segment Item #13: W88-24: Allowable based on cold yield Sy may be un-conservative See Also Loads and Load Sets - AutoPIPE Bentley AutoPIPE