Applies To Product(s): AutoPIPE Version(s): ALL; Area: Warning Date Logged & Current Version March 2020 12.02.00.14 Problem: The following is displayed when using AutoPIPE * * * W A R N I N G - MODEL * * * W2164-124:B31 App J: Stress intensification factors for Reinforced, Unreinforced, Contour and Fitting tee types require D/T < 50 and d/D <= 0.6. The tees mentioned below does not fulfill this criteria: A03 Why and How to avoid it? Solution: This warning refers to a part of Note 7 on page 22 of ASME B31J-2017: See Also "Warnings" Messages Bentley AutoPIPE
↧