Quantcast
Channel: AutoPIPE
Viewing all articles
Browse latest Browse all 16073

Wiki Page: "Warnings" Messages displayed in AutoPIPE

$
0
0
W21-21: Cannot perform this operation, multiple points selected W21-32: Cannot split segments, maximum number of segments reached W21-34: This function can only be applied on junction of two segments W21-38: This function cannot be applied at the current point. W31-86: No allowable stresses are available for the selected material in the material library W36-14: Support will be hidden since all gaps > Gap Scale Factor x Pipe O.D. W41-27: Parameters are outside the applicable range W72-1: AutoPIPE Error Handling W79-85: 0 Stiffness in direction of imposed harmonic load. at XXX W97-99: No analyzed pressure cases present. Only axial GR stress is added W97-213: Corroded thickness is required for sustained stress in B31.3 W177-22: Time history duration is less than first period W214-1: The combination data file (*.CMB) you are about to open was created in a different version. W507-14: Modal analysis cannot be performed. Number of modes is zero W507-40: No temperature case found for non-linear hydrotest. W507-43: No pressure case found for non-linear hydrotest W511-67: Hydrotest load cases have been removed from existing analysis sets and new hydrotest loadset has been added. W726-2: Gap orientation has changed for guide at point XXX W726-6: Near zero length element at point XXX W726-7: Pipe diameter change without a reducer at point XXX W726-8: Kink in straight run of 90.0 deg at point XXX W726-8: Kink in straight run of 179.9 deg at point XXX W726-10: User SIF required at junction at following point(s) W726-12: Following Segment(s) not connected to other segments and has no anchors W726-14: No anchors in current system W726-34: Inconsistent coordinates were reset at following point(s) W726-38: Allowable at ambient is outside of temperature range at point XXX for material YYYY W726-39: Allowable at XX is outside of temperature range at point XXX for material XXXX W726-55: Creep data for (xx) is above temperature range. Zero allowable used at point (xxx) for material (yyyy) W726-93: Zero weight flange found at point XXX W726-94: Zero weight valve found at point XXX W726-110: Not all gaps are non-zero for following support(s) W726-170: The tee at point A04 has only two legs defined which may not meet the conditions to apply the equations for SIF and other stress indices. W726-195: Support D10 1-Zero length from 'supported' to 'connected' point W726-205: SIF and flexibility factors have not been validated for D/t > 100 W727-2: Temperature is outside the range specified the code for Expansion W727-3: Temperature is outside the range specified by the code for allowable W754-1: Sweep angle is 180 degrees W774-47 One or more combinations are set to none W801-14: No frequency below cutoff value W801-58: Smallest timestep for xxxx .TIH file = .... W801-121: V-stop liftoff(s) have occurred under operating W831-11: Seismic level includes cases not analyzed W961-12: System near capacity, please save W2014-35: Previous "to" must be the same as current "from" point W2018-11, W2018-12, W2018-16: Not authorized for ???? edition, AutoPIPE reverts to DEMO mode W2143-7: The joint information of User SIF or flange will be ignored at following point(s) W2143-37: Extremely high value for Displacement tolerance > 1000 detected in loadset W2143-41: Undefined case referenced for concentrated force found at point.. W2143-45: A Yield(Sy) value of less than or equal to 1.00000 psi is detected on some points W2143-76: Friction scale factor is zero. Friction at all supports will be ignored for following analysis set W2143-108: Stress Range factor > 1 is not allowed for non-ferrous materials. At Pipe(s) W2143-121: Sc > 20 ksi (138 MPa). In calculation Sc will be set to 20 ksi (138 MPa) for expansion allow for pipe(s) W2143-123: Sh > 20 ksi (138 MPa). In calculation Sh will be set to 20 ksi (138 MPa) for expansion allow at following point(s) W2164-12: System contains Gaps/Friction/Soil data. Please enable non-linear option in the following Analysis sets W2164-30: Outside diameter does not match with soil properties at following point(s) W2164-58: Soil ID: xxx ,Bedding const. K cannot be zero. Reset to 0.1 W2164-93: The value of "Fluid Density Factor" is zero in following analysis sets W2164-94: The validity of SIF data is only demonstrated for a Do/tn ratio less than or equal to 100 W2164-104: Yield values are zero for the selected material W2164-106: The following pipe ID's are using a depreciated fatigue curve, limited to 1E6 cycles W2164-124: B31 App J: Stress intensification factors W2164-159: The value of "Stiffness" or "Spring Rate" is zero W2164-181: B31 App J: The following tee(s) contain a primary or secondary node on the branch leg W2164-204: The following flange(s) do not consider corrosion W2182-4: Valve/reducer/flex joint should have flanges at both ends W2182-26: Pressure rating on mating flange to a valve is not the same at point xxxx Also See: Warnings, Errors, Crashed, Confirm Messages in AutoPIPE

Viewing all articles
Browse latest Browse all 16073

Trending Articles



<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>