Forum Post: Re: Warning message (W726-10: User SIF required at junction at point )

$
0
0

Hello Lucky,

This is only a warning for the user to know that a specific pipe joint is beyond the typical SIF calculations required by the selected piping code. Even if you do specify a user SIF at the location the warning message will still appear. Again, it is only a warning for the use to know that attention is needed, but if already addressed/accepted then can be ignored on the model consistency check report.

Regards,

Mike Dattilio

Bentley Technical Support Analyst
Web: http://selectservices.bentley.com/

Create your Service Request online!  Log in to SELECTservices Online via http://selectservices.bentley.com/ and then go to My Support Account > Service Request Manager.  You'll have the ability to create a new Service request, view all Service Requests created by you or anyone else in your company, and view statistics on previous requests.