Hello, I have an Autopipe model in AP 2023 that I interface with Staad using SQLite Pipelink. I have several user defined sections in Staad, which used to be properly imported in Autopipe v12.08.00.063 but it is no longer the case. In Autopipe 2023, (23.00.01.367) those sections appear as "Standard" although it is not the case. Inertia values are 0 and the materials are not always defined. Do you have any idea on how to solve this? Please note, it is not a viable workaround to redefine each section by hand as I will have a fair number of them. I have attached two screenshots to show the differences between the 2 versions of Autopipe. Thank you in advance for your help. Regards, Robin
↧