Applies To Product(s): AutoPIPE Vessel Version(s): 44.00.01.014 Environment: N/A Area: Error Original Author: Bentley Technical Support Group Problem: The following occurs when I perform the Strength Calculations: Error Code 795 - API 650: design temperature >93 0 C. How to fix it? Answer: AutoPIPE Vessel can design tanks for maximum design temperature only up to 93 deg C. Storage tanks with design temperature higher than 93 deg C but lesser than 260 deg C shall be designed as per API 650 Annex M. Unfortunately, As of April 2024 Annex M is not covered in AutoPIPE Vessel. Feature 639739 is created against this request and will be available in future release of the software. See Also Bentley AutoPIPE