Wiki Page: W726-8: Kink in straight run of 90.0 deg at point XXX

$
0
0
Applies To Product(s): AutoPIPE, Version(s): 2004, XM, & V8i Environment: N/A Area: Warning Message Subarea: Original Author: Bentley Technical Support Group Problem: The following is displayed in model consistency check report: W726-8: Kink in straight run of 90.0 deg at point XXX Note: angle may change but uses the same avoidance measures. Solution: This warning message is displayed whenever the incoming pipe axis does not exactly match the out-going pipe axis in a absolutely straight line through the indicated node point. Avoidance: Option #1: Select the indicated node point and change to a Bend point, Modify> Convert Point To...> Bend. Option #2: User is trying to model a piece of equipment with piping and assign "Rigid Properties Over Range". If this is correct, review the indicated node point to be sure warning message can be ignored. Option #3: Select the indicated node point and Delete it from the model.