Wiki Page: 03. Would you please explain to me what is the difference between ambient and room temperature for TTA in AutoPIPE?

$
0
0
Applies To Product(s): AutoPIPE, Version(s): 2004, XM, & V8i Environment: N/A Area: Load Case Subarea: Original Author: Bentley Technical Support Group Problem: Would you please explain to me what is the difference between ambient and room temperature for TTA in AutoPIPE? Answer: The difference in the terms is only introduced based on from where the term was incorporated i.e. Alpha and Modulus values for pipe states room temperature after NB-3653.2. These two terms are used in automatic gross discontinuity calculations only. Generally room temperature and ambient temperature are synonymous, and represent the temperature associated with the location where the system is located. See Also Bentley AutoPIPE External Links Bentley Technical Support KnowledgeBase Bentley LEARN Server Comments or Corrections? Bentley's Technical Support Group requests that you please submit any comments you have on this Wiki article to the "Comments" area below. THANK YOU!