Wiki Page: 04. What is the correct ambient temp for use with TTA analysis in AutoPIPE?

$
0
0
Applies To Product(s): AutoPIPE, Version(s): 2004, XM, & V8i Environment: N/A Area: Load Case Subarea: Original Author: Bentley Technical Support Group Problem: WE could have a room temperature in a building, in winter that is not heated where the piping system is located, and the temperature could be 50 F whereas outside it could be -20 F, In this case what would be the ambient temperature? Answer: In this case it will be fair to say that ambient temperature is 50 F i.e. temperature of the surrounding environment where the system is located. This will be used in defining the thermal flux of outside of pipe wall. See Also Bentley AutoPIPE External Links Bentley Technical Support KnowledgeBase Bentley LEARN Server Comments or Corrections? Bentley's Technical Support Group requests that you please submit any comments you have on this Wiki article to the "Comments" area below. THANK YOU!