Applies To Product(s): AutoPIPE Version(s): 2004, XM, V8i Environment: N/A Area: Subarea: Original Author: Bentley Technical Support Group Date Logged & Current Version Jan 2015 09.06.01.10 Problem: AutoPIPE results does not seem to consider the pipe properties wall thickness with regards to Corrosion Allow. or Mill tolerance, only the Hoop Stress changed, why? Answer: With AutoPIPE V8i 09.06.01.xx and lower, check your setting for Tools> Model Options> Results> "Use nominal thickness" check box. This would control what wall thickness is being used in your calculations. Review the online help for details on this setting. See Also Bentley AutoPIPE External Links Bentley Technical Support KnowledgeBase Bentley LEARN Server Comments or Corrections? Bentley's Technical Support Group requests that you please submit any comments you have on this Wiki article to the "Comments" area below. THANK YOU!
↧