Wiki Page: 07. Thermal loading does not seem to be applied in the axial direction in AutoPIPE model, why?

$
0
0
Applies To Product(s): AutoPIPE, Version(s): 2004, XM, & V8i Environment: N/A Area: Settings Subarea: Original Author: Bentley Technical Support Group Problem: In my simple model with an Rigid Anchor - Pipe - Rigid Anchor, with when a thermal load case is applied should expect high Code Stresses for Max Range at the anchors, however it appears that AutoPIPE's is not calculating the results correctly, why? Answer: Most of the time this is because of an AutoPIPE setting, see the following: For AutoPIPE V8i 09.06.01.xx and lower: See Tools> Model Options> Results> Include axial force, enable this check-box option (see online help for details about this setting). Results with this Setting Turned On: See Also Bentley AutoPIPE External Links Bentley Technical Support KnowledgeBase Bentley LEARN Server Comments or Corrections? Bentley's Technical Support Group requests that you please submit any comments you have on this Wiki article to the "Comments" area below. THANK YOU!